8.3 Weighing Specifications
Capacity Range: 2Lbs (1Kg) to 500,000 Lbs (250,000 Kgs)
Input Range: 0.5mV/V to 3mV/V.
Internal Counts: 10,000,000(Nom.) 16,777,215(Max.)
Display Counts: Up to 100,000 / 10,000 recommended for stability.
Input Sensitivity: 2µV per display graduation (using 2mV/V input @
10,000 display counts)
Formula: Sensitivity = ((mV/V*excitation voltage)/
Display counts)
Linearity: .01% of full-scale capacity.
Overload: 105% of full-scale capacity.
Load Cell Excitations:(Standard): 10VDC @ .5A max.
(Up to 9-350load cells).
Load Cell Excitation: (Optional): 10VDC @ 1.5A max.
(Up to 27-350load cells).
Calibration: 2-step keyboard digital, or direct coefficient
entry.
8.4 Communication Specifications
Ports: Three RS-232 Full Duplex/Individually
Configurable. Optional RS485 or 10 BaseT
Ethernet on COM1.
Baud Rate: Port Selectable: 1200 – 115200 bps.
Up to 10Mbps on Ethernet.
Start/Stop Bits: Fixed at 1 for all ports.
Parity: Port selectable: Even, Odd, or None.
Word Size: Port selectable: 7 or 8 bits.
Flow Control: None.